EMI/EMC Laboratory
ERDA with its state of the art EMI/EMC laboratory is carrying out evaluation for various commercial and defense EMI/EMC requirement of wide range of products as per Indian, International and MIL standards.
Electrical Research and Development Association
01
Infrastructure
- 10 meter Semi Anechoic Chamber with 60 V/m Field Strength, 5 Meter Diameter, 3 MT Load Capacity
- EMI Test Receivers – 20 Hz to 26.5 GHz
- Artificial Mains Network – 100 A, 9 kHz to 30 MHz
- Signal Generators – 9 kHz to 22 GHz
- Power Amplifier – 10 kHz to 18 GHz
- Antenna – 10 kHz to 18 GHz
- Absorbing Clamp – 30 MHz to 1000 MHz
- Isotropic E Field Probe – 10 kHz to 40 GHz, 800 V/m
02
Evaluation as per MIL standard (DoD Test codes – MIL – STD – 461 E/F)
List of evaluation at laboratory
Evaluation as per MIL standard (DoD Test codes – MIL – STD – 461 E/F)
Approved by Integrated Headquarters, Ministry of Defence (Indian Navy)
- Radiated Emission (RE 101, RE 102)
- Conducted Emission (CE 101, CE 102)
- Radiated Susceptibility (RS 101, RS 103)
- Conducted Susceptibility (CS 101, CS 114, CS 115, CS 116)
Evaluation as per Commercial standard
- Radio Interference/Disturbance Measurement
- Electrostatic Discharge Immunity test setup
- Radiated, Radio Frequency, Electro-magnetic Field Immunity test setup
- Electrical Fast Transient/Burst Immunity test setup
- Harmonic & Flicker Measurement
- TEC accredited evaluation for Telecom Equipment
03
Energy Meters, Multifunction meter
Relays and Switchgear Panels
Timers, Motors, Submersible Pumps
Assemblies for Rocket Launcher
VDSL – Ethernet Modem, Telecommunication product
Control panel for window wiper with RCU
Control Panel for defense system
UPS, SMPS and other power module
Electric Control System (ECS) for air inflation system
Electrical Vehicle charger